Decarbonizing Drilling Operations
Emissions Reporting
Energy Efficient Lighting Solution
ALTERNATIVE ENERGY
ALTERNATIVE FUELS
ENGINE & POWER MANAGEMENT
Digitization / AI
Fuel Enhancer
ILLUMIC
PowerTAP
Our goal is to deliver responsible hydrocarbon production with smart, sustainable solutions. That's energy without compromise.
Rig Electrification
Contact Us
Advisory Real-time AI peak power predictions, interface with EDR systems and notifications.
Control Manages the generators by automating the start and stop of the engines.
Maintenance Engine condition-based monitoring, alerts via RigCLOUD, work order scheduling, interfaces to Asset Management systems, and choice of engines to run.
How Does It Work?
Scroll to Top
SmartPOWER™
SmartPOWER Delployed at Rig
• EDR DATA • ENGINE ECM • GENERATOR DATA
• ADVISORY AI • ENGINE DERATE AI
INPUTS
Intelligence
• Engine Recommendation • Engine Automation • Maintenance Monitoring
Outputs
HMI In Drillers Cabin
Overview
By utilizing SmartPOWER with engine condition monitoring equipment, data can be transferred to the cloud to track engine management practices, fuel usage and emissions. Key Performance Indicators are consolidated in a End of Well Report accessible via RigCLOUD.
Engine Management
Lighting System
Digitalization / AI
Reduce Emissions
Reduce Fuel Costs
Reduce Engine Hours
Focus on Drilling or Refocus Crew Efforts
AI
Analyzes/Evaluates data of the engine condition, EDR, current and past operations and rig power limit
Informs the Rig
Recommends or automates how many engines will need to run
Automates the Engines
Recommends action or automates engines on/off feature based off prediction
Harnessing A.I transforms rig power, engine management
Low-carbon technologies moving from concept to reality at the rig site
Nabors Develops Advanced Optimization Features for Smarter Engine Management.
MEDIA & NEWS
Fully Autonomous
By connecting to the rig's generator control system, we can fully automate engine management.
Up to 15% GHG Emissions and Fuel Consumption
Efficient engine loading can lead to lower emissions and fuel costs.
10-Minute Look Ahead
Using data collected from the rig, we provide a proactive approach giving the driller a 10-minute look ahead predicting operational changes and power requirements.
Improved Engine Maintenance
Using an engine management system can extend regular time-based maintenance intervals through a reduction in engine operating hours.
CASE STUDY
Learn More
South Texas Case Study
Operator reduces emissions impact of drilling operations in South Texas by improving the fuel efficiency of diesel power generation systems.
Rigs Upgraded with SmartPOWER Technology
Argentina
Colombia
Saudi Arabia
United States
103
Manual dosing
Maintenance work order scheduling, engine condition-based monitoring, alter via RigCLOUD, interfaced with AM systems.
The diesel fuel enhancer is dosed into the engines combustion chamber where it is measured and reported on. There are two options for dosing:
Connect the nanO2 skid to fuel tank
US install base - 89 rigs across below Basins
East TX
Columbia
Built in HMI dashboards include real-time engine, generator and SmartPOWER advisory along with past 24-hour engine and generator usage.
Automated fluid dosing with digital KPI’s deployed at the edge track real time savings and engine performance.
Cleans fuel injectors and removes carbon deposits by burning off existing carbon deposits. Reduces particulate matter up to 37%
Reduce Up to 23% CO & 43% NOx emissions, providing additional oxygen for a more complete burn. Reduce up to 37% particulate matter.
Increased fuel efficiency up to 8% by increasing the quality of the fuel through cetane improvers.
What can nanO2 do for you?
SmartPOWER Delployed Rig
IMPUTS
MODULES
• kWh / Gal METRIC • RUN TIME
TRACKING
The growing need for cleaner fuels is an accelerating development for businesses looking to reduce their impact on the environment. The nanO2 fuel enhancer is a proprietary and patented additive catalyst that enhances the combustion process of diesel engines
South TX
Permian
Apalacia
Bakken
INTERNATIONAL install base -
Onshore
Completions
Production
Offshore
Application Areas
Automated dosing
6.7%
5%
Average Increase in Fuel Efficiency
5.4%
Latin America
Land Rigs
Increase in Fuel Efficiency
Canada
Mexico
Oman
UAE
Turkey
Papua New Guinea
Gulf of Mexico
Brazil Offshore
Proven Field Results
A drilling customer saw a 6.4% savings of emissions and fuel consumption.
Colombia Case Study
West Texas Case Study
Completions operation saw a 5.4% savings on emissions and fuel consumption.
Awards
Canrig wins special award for engineering innovation for nanO2
nanO2 Scaling up to Decarbonize Operations
nanO2® Fuel Enhancer Saves 1,700 mt of CO2e on Initial Nabors Rigs
Target Markets
Increase Engine Performance
Improve Fuel Efficiency
Reduce Combustion Temperatures
up to 8%
Up to 8% savings in fuel consumption and emissions reduction by increasing the fuel quality through cetane boosters and a combustion catalyst.
23%
43%
CO Emission Reduction
NOx Emission Reduction
up to 37%
Particulate Matter Reduction
Additionally reducing the particular matter up to 37%.
Automated fluid dosing with digital KPI’s deployed to track real-time savings and engine performance.
Argentina Case Study
Dual fuel power generation system saw a 5.4% increase in fuel efficiency and emission reduction.
Third-Party Emissions Validation
Using a third-party real-time emissions monitoring equipment, we validated nanO2 emission savings on rig in South Texas.
East Texas Case Study
Customers can access detailed analytics and monitor fuel usage and fuel savings through the system's web portal on any device using Emerson’s Zedi platform.
up to
Emissions and Fuel Reporting
Indonesia
Australia
North Africa
North Sea
Advisory real-time AL peak power predictions, interface with EDR systems and notifications.
Control Generator management system selects which engine to run based on performance, hours and scheduling.
Product Specifications
High-Efficiency Lighting
ILLUMIC offers more reach and foot candles per square foot than any other conventional system, replacing an equivalent of up to six diesel light towers on-site.
De-rating module assesses service life, altitude, coolant temperature, oil and filter conditions, and other factors of each engine to rate the available power capacity based on its specific conditions.
10-minute look ahead predicting operational changes and power requirements.
Improved engine maintenance & fully automated solution available by connecting to rig generator control system.
Decreased Fuel Consumption. Reduced GHG Emissions (up to 6% reduced) with efficient engine loading without an ESS.
What can SmartPOWER do for you?
The ILLUMIC™ Lighting System is designed to maximize workers’ visibility and overall wellsite illumination, using energy efficient and maintenance free LED fixtures. ILLUMC offers more reach and foot candles per square foot, replacing an equivalent of up to size diesel light towers on-site. The system offers a fit for purpose, retrofittable design that does not impact the rig's crown footprint.
Reduces 213 Kilowatts per Hour Lowering Emissions.
LED Life Span 10+ Years.
Seamless Installation With Our Custom Crown-Mounted Framing
kWh of Energy
213
Gallons of Fuel
29
Equivalent to
18,000 Smartphones Charged
640 Miles Driven Gasoline Vehicle
Foot-Candles
2-4 ft/c
4-6 ft/c
6-9 ft/c
Increase Safety
Reduce Rigsite Emissions and Noise
Maintenance-free LEDs
Lower Energy Consumption
Saves up to 29 Gallons per Day.
Rigs Equipped With ILLUMIC
7-10 ft/c
9-11 ft/c
10-12 ft/c
25 ft
50 ft
75 ft
Per OSHA, lighting standards provide at least 5-foot candles (fc) of illumination in walking areas and 10 fc in working areas.
100 ft
150 ft
200 ft
Illumic Performance Data
*These results are based on single operation.
Hover over foot candles to see illumination distance.
100
+
Deployable on any AC land rig
Highline Power Transformer Module
Canrig’s PowerTAP Highline Power Module reduces cost and emission by connecting the highline power grid to the drilling rig, powering all electrical components without the need of diesel generated power drilling rig. Manufactured to meet IEEE standards and as many utility provider requirements as possible, which includes transfer switch for easy switching between utility power and generator power.
Reduce noise pollution by eliminating the need for diesel or natural gas-powered gen-sets.
Eliminate the use of diesel power generation on the well site reducing the on-site GHG emissions from gen-sets to zero..
Anywhere highline power is available, easy to install with stand-alone cable reel.
Zero scope 1 emissions from rig.
Connect your Rig to the Grid
PowerTAP™
Where highline power isavailable, the Canrig PowerTAP module can be installed on rigs to accept grid power. It interfaces with the VFD powerhouse system, directly providing all electric power quickly to the rig without the need to run generators. PowerTAP is designed toprovide system resiliency through the option to switch to diesel generators in the case of utility grid failure.
Alternative Energy
Tempature Rating
PowerTAP Specifications
Nabors and Hess Electrify Bakken Drilling Operations
Highline Power Module
Minimal On-site Scope 1 Emissions
Shift Quickly Between Grid and Engine Power
Retrofittable, Portable and Easy to Install Skid
Reduce Noise Pollution
Estimates Up to 70% Reduction in Energy Costs
Estimates Up to 50% More Efficient GHG Emissions
Voltage In
supports up to 33 kV
IEEE 519 Rated
Harmonic Filtering
4MVA-Liquid Filled Substation Transformer
Transfer Rating
Optional 50/60 Hertz
Frequency Conversion
PowerTAP installed anywhere multi-voltage and frequency available
Easy to install stand-alone cable reel to connect into the utility power
Mounted substation transformer for easy transport
High Voltage Cable Reel
Utility Power
PowerTAP Highline Power Module
Connected to PowerTAP with the ability to quickly switch to engine power
Existing Diesel Generators
Operation runs on utility power reducing scope one emissions to nearly zero
Rig Operation
PowerTAP Process
PowerTAP Units Deployed Across the United States and Latin America
27
based off the efficiency of ERCOT utility grid*